Sherwin-Williams

January 24, 2024

Innovation in oil and gas tank coatings in an ever-moving industry

Tank linings are the workhorses of asset protection in the oil and gas market. These coatings provide a critical barrier between a stored product and the tank in which it is contained. Without them, the risk of corrosion and material degradation is high, which is why Sherwin-Williams Protective & Marine offers lining solutions for nearly every asset in the oil and gas supply chain.

There are several factors to consider when specifying tank linings for the various assets at each stage of the value stream. Performance requirements, such as temperature and chemical tolerance, and corrosion resistance will dictate the type of tank lining needed to protect processing equipment, transport vessels and storage tanks. Commercial and market conditions, such as supply, demand, resource availability and budgets, can also influence tank lining specifications.

In today’s oil and gas market, applicators and asset owners must adapt to changing demands, limit downtime and balance resources to remain profitable, all while complying with American Petroleum Institute (API) standards. Selecting the right tank lining can generate long-term savings for both parties, which is why it is important to understand the technology and development behind modern or “next-generation” linings.

The history of tank linings

Since the 1980s, technological advances have changed the way chemicals are processed and stored, particularly in the oil and gas market. Sherwin-Williams has been an industry leader in lining development for more than three decades and was one of the first companies to bring a solvent-free epoxy lining to market. Sherwin-Williams also pioneered linings with a rapid return to service through its Opti-Check™ optically active pigment (OAP) and styrene-free vinyl ester technologies.

For the history of linings in the coatings industry, see Table 1, which outlines chemical-resistant lining technologies and specifications over the past several decades.

TABLE 1: HISTORY OF CHEMICAL-RESISTANT LININGS

YearSpecification technologyProperties
Pre-1980Coal Tar Epoxieso Classified as a carcinogen in the U.S. in 1980
o Used in crude oil and water immersion.
Pre-1980Thin-film epoxieso Low solids and multiple coats required
o Used for crude oil and white oil storage at ambient temperature.
Pre-1980Reinforced lining systems (epoxies and polyesters)o Complex application
o High cost
o Refurbishment plans and extended service life.
1980sFirst-generation solvent-free epoxieso Poor application properties
o Used for crude oil and white oils at ambient temperature.
1980sGlass flake Vynil esterso Extreme health and safety issues
o Only option for high-temperature, high-pressure process vessels
o Prevalent when CO2 injections were causing problems
1990sSecond-generation solvent-free epoxieso Used for crude oil and refined petrochemicals.
o The first linings to offer a “proven” long life cycle for maintenance and new construction applications
1990sFirst-generation epoxy phenolic novolacso Able to withstand high temperatures and high pressures
o Medium solids
1990sFirst-generation solvent-free epoxy phenolicso Plural-component and single-leg applied linings for high-temperature service
2000MIL-PRF-23236 introducedo Requirement established to ensure longer lining life and easier inspection.
o Inspection methods are introduced for edge-retentive linings.
2000sSolvent-free epoxies for ballast and naval fuel under MIL-PRF-23236o First use of solvent-free linings in the U.S. Navy.
2000-2010sNovolac epoxieso Proven long service life for these systems since their launch
o Edge retention and optical inspection techniques become standard in high-performance tank linings

Changing performance requirements

Performance requirements for oil and gas protective linings have changed dramatically since their inception. Before tank linings were used, crude oils, heavy fuel oils and diesel were considered non-corrosive, a theory that was proven wrong when water and acid contamination led to severe corrosion and «pitted» tank bottoms. In addition, earlier lining technologies did not address microbiologically influenced corrosion, which is a major source of internal corrosion in mild steel storage tanks in several markets.

See Table 2 for additional changes in performance requirements.

TABLE 2: CHANGES IN LINING PERFORMANCE REQUIREMENTS 1960S – PRESENT

VARIABLEMID-TO-LATE 20TH CENTURY2010s
ChemicalCrude oil – heated for loading and unloadingShale oil and sour or higher-temperature crude oils
StorageStorage of simple and refined petrochemicalsBiodiesel (vegetable oil-based): alcohol and acid content is a concern
TanksOften unlined, as the corrosive nature of crude and refined petrochemicals was underestimated.Modifications with bioethanol and other alcohols can have a negative effect on the welds of mild steel storage tanks.
Fuel additivesOxygenates (ethers, etc.), fuel dyes, antioxidants, etc., have changed the effect fuel has on linings and steel.

Many of the additives are diluted with methanol, which makes the fuel much more aggressive and damaging to traditional linings.
Unleaded gasoline is more aggressive to linings and mild steel tanks due to its alcohol content.
Purity of stored materialInitially, simple requirements for drinking water (taste and appearance) and aviation fuels.Increased global purity requirements for drinking water (low permitted extraction limits) and high-purity demands for aviation fuel cited in the EI 1541 Standard.

The purity of other chemicals is another growing demand going forward (e.g., sulfuric acid and glycols).
Increasingly aggressive nature of crude oilN/AHigh-sulfur crudes: amine scrubbers.

Greater volume of crude oil transported by rail.
Increased demand for long-life liningsN/AThe performance of quality linings is confirmed when tanks come out of service

Advances in technology, a broader understanding of chemistry and significant updates to legislation require linings to provide greater chemical and temperature resistance over a longer period. After years of studying field performance, industry experts understand the characteristics required of modern oil and gas linings, not only during the construction stages, but also during post-construction and maintenance.

This in-depth knowledge has enabled oil and gas professionals to make smart, informed decisions when choosing the right lining. Having demonstrated superior performance, ultra-high solids (UHS), solvent-free and edge-retentive linings are now the standard, which increases flexibility and improves service life expectancy.

Achieving API standards

Tank linings must meet life cycle requirements in order to comply with API standard guidelines. API provides a framework and guidance on the construction, protection and inspection of aboveground steel storage tanks. See Appendix A for API guidance on tank linings.

PERFORMANCE CHARACTERISTICS OF MODERN LININGS

When introducing any new product to the market, Sherwin-Williams analyzes its end use and identifies ways in which the product can be safer, more reliable and more cost-effective within its application. For tank linings, Sherwin-Williams designs products with long service life, ease of inspection and ease of application as a priority.

LONG SERVICE LIFE

Sherwin-Williams can deliver better service times and improve life cycle costs by developing coatings that have greater flexibility, chemical resistance and edge retention. As a full-service solutions provider, Sherwin-Williams is committed to optimizing and evolving its robust product portfolio to ensure long-term assets and investments are protected.

EASE OF INSPECTION

For tank linings, inspection processes must be considered at an early stage. In accordance with the Society for Protective Coatings (SSPC) TU 11 standards and in collaboration with leading UV flashlight manufacturers, Sherwin-Williams has developed linings with OAP technology. These linings provide efficient and effective visual inspection of epoxy coatings for industrial applications. Sherwin-Williams has also developed linings with superior edge retention to ensure materials perform at optimal levels following inspection.

EASE OF APPLICATION

The demand for greater productivity has led to the development of products that can be applied during wider application windows, within broader temperature and humidity ranges, and in multiple coats in one day. Sherwin-Williams has formulated products for easy application and rapid return to service.

PURITY

The ability to maintain purity in key materials in the oil and gas industry is crucial. Sherwin-Williams’ new tank lining technology complies with the globally recognized EI 1541 standard: Requirements for internal protective coating systems used in aviation fuel handling systems, which includes several strict purity requirements that must be met once fuel has been exposed to the lining.

The “Next generation» of tank linings: NOVA-PLATE® 360

Lining technology is always changing. Simply replacing what came before is not an option: it is important to improve and evolve linings to meet changing market requirements.

With the increasing demands of the oil and gas industry (temperatures, pressures and exposure to aggressive chemicals), Sherwin-Williams has developed Nova-Plate 360, a flake-reinforced novolac tank lining. This highly cross-linked lining uses the latest multifunctional curative and novolac technology and is the first product of its kind.

Nova-Plate 360 provides exceptional resistance against increasingly aggressive solvents and can withstand higher temperatures and pressures. This lining minimizes asset downtime and saves time during the inspection process.

Sherwin-Williams carried out the product development process with the following intentions in mind:

  1. The polymer (resin) system was optimized to deliver chemical resistance without compromising flexibility, a key requirement for long lining life, pot life and cure time.
  2. The pigmentation was selected to safeguard chemical resistance and barrier properties. Advanced technology was used to bond the pigments to the resin, which improves performance and reinforces the film while maintaining the viscosity required for all common application methods (airless, plural and others).
  3. Aluminum oxide was incorporated to improve abrasion resistance.
  4. PTFE, a hydrophobic additive with exceptional chemical resistance, was included to optimize and improve cleaning properties without affecting the lining’s ability to adhere to steel or the properties of the coating.
  5. Opti-Check™ OAP was incorporated to aid inspection, reducing reliance on high-voltage spark testing.

All of these characteristics were precisely fine-tuned and balanced to ensure that performance and application characteristics were not compromised. A key competitive lining was used as a benchmark during each stage of development to ensure that performance was ahead of current products on the market.

For reference, Table 3 shows the test results for Nova-Plate 360.

TABLE 3: NOVA-PLATE 360 PERFORMANCE TESTING

TYPES OF TESTS TESTS COMPLETED
Application and inspection
1. Airless spray (low ratio)
2. Airless Plural
3. OAP demonstration
Mechanical properties1. Hardness
2. Adhesion to steel
3. Adhesion to self
4. Impact
5. Flexibility
6. Abrasion
7. Edge retention
Isothermal immersion testingNACE TM0174 and ISO 2812 – for approvals and chemical resistance guide – extensive third-party testing has been carried out
Autoclave testingThird-party testing in mixtures of hydrocarbons, water and acid gases

Nova-Plate 360 and API

For storage tanks, it is vital to follow API 652 for the correct selection and application of linings according to service and substrate conditions. Sherwin-Williams has extensive experience with tank linings, which has enabled it to design Nova-Plate 360, a long-life lining that complies with API 652.

Standard storage tank inspections will remain an API 653 requirement to ensure optimal service life. Comprehensive lining design can also be used to simplify the inspection process through the following characteristics:

  1. By intentionally designing Nova-Plate 360 to be abrasion resistant and easy to clean, this lining simplifies the emptying, cleaning and inspection processes. Ease of cleaning and reduced damage can deliver significant time and cost savings over the life of the tank.
  2. Optically active pigment enhancements offer benefits during application, as the lining can be checked for holidays. The use of UV lamps during planned inspections will also identify any lining damage that may not be visible to the naked eye, especially since spark testing is not recommended after service.
  3. New in-situ methods are emerging that allow faster predictive inspection of storage tanks. Nova-Plate 360 is designed to be compatible with such inspection techniques. These methods are accepted as API 653 compliant and, combined with long-life linings, offer huge potential savings in inspection costs over the projected service life of a tank.

Meeting the need for longer service life

To meet market demands, Sherwin-Williams needed to develop a new product that integrated novolac chemistry with binder technology. Nova-Plate 360 meets these stringent market requirements in terms of performance and price, and exhibits improved application properties.

Not only does Nova-Plate 360 save time through application and curing, but its OAP technology immediately identifies holidays and missed areas, allowing rectification on the spot. The UHS technology and capability also allow application across a wide range of thicknesses (15 to 50 mils), which makes this lining suitable for both new construction and maintenance projects where application over pitted surfaces is required.

The ability to resist aggressive materials has become increasingly important for 21st-century tanks, which often contain biofuels and oxygenated gasoline. Unlike its predecessors, Nova-Plate 360 can resist these aggressive chemicals at high temperatures and pressures, demonstrating its superior performance and high end-use versatility.

API 652 and API 653 are likely to remain the key lining selection and inspection standards in the market for quite some time. By developing products based on new technologies, iterations and learnings, Sherwin-Williams has shown that time and cost savings can be achieved. This product has demonstrated that next-generation linings can reduce complexity for owners and specifiers.

Sources

  1. API RP 652 Linings of Aboveground Petroleum Storage Tank Bottoms, Fifth Edition
  2. API Std 653 Tank Inspection, Repair, Alteration, and Reconstruction, Fifth Edition, Includes Addendum 1 (2018), Addendum 2 (2020), and Errata 1 (2020)
  3. EI Standard 1541 Requirements for internal protective coating systems used in aviation fuel handling systems
  4. MIL-PRF-23236D, Performance Specification: Coating Systems for Ship Structures (15 Sep 2009)
  5. ASTM D4541-17> Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers
  6. NACE TM0174-2002, Laboratory Methods for the Evaluation of Protective Coatings and Lining Materials on Metallic Substrates in Immersion Service
  7. ISO 2812-2:2018 Paints and varnishes — Determination of resistance to liquids — Part 2: Water immersion method
  8. TM0185-2006-SG, Evaluation of Internal Plastic Coatings for Corrosion Control of Tubular Goods by Autoclave Testing

APPENDIX A: API STANDARDS

API provides a framework and guidance on the construction, protection and inspection of aboveground steel storage tanks, including:

  • API 650: Provides guidance on tank construction
  • API 651: Suggests the best use of cathodic protection
  • API 652: Reviews the types and selection of linings for storage tank protection.
  • API 653: Provides guidance on inspection intervals and how linings can help extend them.

API 652 provides detailed guidance on selecting a lining and partial direction on the type of lining to be used, but ultimately, lining selection is decided by the specification or the engineer. Lining selection is left to the supplier, considering that generic linings may not have the same performance.

API 652 is based on the following criteria:

  1. Substrate condition
  2. Tank history (including repairs, settlement, previous cargo)
  3. Stored material (temperature, approvals, purity and flexibility)
  4. Durability

API 652 also emphasizes the importance of surface preparation and application in achieving the desired lining performance. Quality lining suppliers will offer high levels of inspection during application to help ensure optimal lining performance.

Each category has different performance and application characteristics.

Subsequent inspections are determined according to a risk-based inspection protocol, measured by corrosion rate; and meeting all the criteria can increase the maximum interval to 15 years.

Thin film (<20 mils [500μm])Thick film (>20 mils [500μm])Reinforced thick film
Traditional solvent-borne epoxySolvent-free epoxySolvent-free epoxy
High-temperature phenolicSolvent-free epoxy phenolicSolvent-free epoxy phenolic
Solvent-free epoxyGlass flake Vynil EsterReinforced novolacs
Solvent-free epoxy phenolic

We use cookies to improve browsing and analyze traffic. You can accept or reject analytics cookies. Privacy Policy