Thermal coatings offer multiple safety advantages for manufacturing facilities

Hazards lurk in many corners of a wide range of manufacturing facilities, but they are especially present anywhere high-temperature equipment is located in close proximity to personnel. Workers can easily burn their skin on hot assets such as pipes, ducts and tanks if facility owners do not take care to isolate that equipment.

Safety enclosures/cages and fences are common isolation solutions that keep people away from hot surfaces. However, they can be costly to install, take up a lot of space and hinder access for maintenance. Alternatively, traditional insulation systems can be used to eliminate bulky cages in favor of slightly less bulky materials, such as mineral wool, which are wrapped around an asset and then jacketed with aluminum or stainless steel. The sealed jacketing is intended to prevent moisture from saturating the insulating material. These insulation systems are effective at preventing burns, but they are costly to inspect and maintain, and at the same time carry a greater risk of developing corrosion under insulation (CUI) when water penetrates the jacketing.

Perhaps surprisingly, a relatively thin layer of insulative coating material can offer an alternative to both insulation and enclosure systems, while providing a number of benefits. Such spray-applied thermal insulative coatings (TICs) have sufficient thermal conductivity properties to keep exterior surfaces safe to the touch, protecting personnel without the need for exterior isolation structures or insulation. They offer the additional safety benefit of protecting workers against slips and falls by reducing the likelihood of condensation forming on coated assets and dripping onto walking surfaces such as floors, steps and walkways. In addition, the coatings effectively eliminate the troubling problem of CUI, which can lead to downtime and dangerous leaks. Importantly, TICs can also provide a degree of heat conservation to potentially keep process heat within coated assets, making them a practical option for many operations.

Burn Protection: How to Prevent Injuries

In high-temperature manufacturing environments, burns are a high-priority concern. A few seconds of incidental contact with a hot surface is all it takes for skin to blister and burn. In fact, the U.S. Occupational Safety and Health Administration (OSHA) sets a maximum skin temperature limit of 60 °C (140 °F) after being in contact with a hot surface for five seconds. No reportable injury will occur below those thresholds. That means any asset located within about two and a half meters of where a worker may be positioned must be protected by a physical barrier, an insulation system or a TIC. It is important to keep that distance in mind, considering that a six-foot-tall person can reach about eight feet with outstretched hands.

By specifying a TIC instead of a physical barrier or a traditional insulation system, facilities can eliminate the fabrication, installation and upkeep associated with those alternatives while still meeting OSHA burn protection requirements. Sherwin-Williams Protective & Marine has a line of TIC solutions, Heat-Flex®, which includes spray-applied waterborne acrylic coatings containing a high volume of engineered ceramic or silica microspheres and low-thermal-conductivity aerogel particles. These elements create low thermal conductivity within the final cured coating. This low thermal conductivity effectively limits the transfer of thermal energy through the coating, preventing people from being burned on assets that house internal fluids and gases at high temperatures. Facility managers should focus on any asset in a plant that has an operating temperature above 66 °C (150 °F). Even dangerously hot systems, such as steam lines and boiler ducts that can reach up to 177 °C (350 °F), can be coated with a Heat-Flex TIC to prevent burns from incidental contact.

After a TIC has been applied and has dried, inspectors can use a thermesthesiometer on the coated asset to confirm that its surface temperature is within OSHA requirements for burn protection. This special instrument is required under the guidelines of ASTM C1057-17 “Standard Practice for Determination of Skin Contact Temperature from Heated Surfaces Using a Mathematical Model and Thermesthesiometer,” since a traditional surface temperature probe will not provide an accurate reading of skin temperature.

Condensation Protection: Reducing Slips and Falls

Because thermal coatings reduce heat transfer to the exterior surfaces of operating assets, there is a smaller temperature differential between those surfaces and the surrounding air. That means there is less chance that a cold or hot pipe will experience condensation on its surface. Such condensation carries a minor risk of affecting the TIC system and the underlying asset, since water in contact with the coatings can eventually lead to corrosion. What is more problematic is that condensation accumulating on assets can threaten worker safety if it drips onto walking surfaces where employees can slip and fall. These incidents are one of the leading causes of accidents in plants.

Several processing operations involve both cold and hot temperature extremes, each of which increases the likelihood of condensation occurring on equipment. However, Heat-Flex TICs can effectively insulate assets operating at service temperatures ranging from -51 °C (-80 °F) to 177 °C (350 °F). This capability helps significantly reduce the temperature imbalances between a surface and the surrounding air that cause condensation. Surfaces should rarely drop below the dew point, minimizing the chance of significant condensation forming, dripping to the floor and causing a fall.

After a TIC has been applied and has dried, inspectors can use a thermesthesiometer on the coated asset to confirm that its surface temperature is within OSHA requirements for burn protection. This special instrument is required under the guidelines of ASTM C1057-17 “Standard Practice for Determination of Skin Contact Temperature from Heated Surfaces Using a Mathematical Model and Thermesthesiometer,” since a traditional surface temperature probe will not provide an accurate reading of skin temperature.

Corrosion Protection: Eliminating CUI

Assets covered with traditional insulation systems face the potential for a problem common to many industries: CUI. Moisture will inevitably enter an insulation system and become trapped there, either from water breaching the outer jacketing or from condensation forming on the surface of the covered asset. This moisture will never dry out, keeping water in constant contact with the substrate. If that substrate is uncoated, the steel is certain to face rapid deterioration, but even a coated substrate can eventually corrode, unless a mitigation solution, Heat-Flex CUI, has been applied, when it is in constant contact with water, especially when that environment is enclosed and at high temperatures. Such corrosion can eventually cause a steam line, for example, to corrode and develop a leak that results in system downtime at best and worker injuries at worst.

Perhaps the biggest concern with CUI is that it is hidden, lurking beneath the insulation or jacketing with limited warning signs of its existence. Therefore, insulated assets must be inspected periodically to confirm that CUI is not a problem. Ultimately, that involves removing portions of the jacketing and insulation to visually inspect the metal surface. Inspectors may also need to assess metal thickness using ultrasonic testing techniques.

The simplest way to eliminate the threat of CUI is to eliminate the insulation altogether, thereby eliminating the corrosion zone between the insulation and the substrate. This effectively removes the “under” in CUI. Insulative coatings such as Heat-Flex TICs allow facilities to do exactly that, since coated surfaces do not require a physical exterior covering. There is no possibility of trapping moisture against metal surfaces, which effectively eliminates the risk of hidden CUI, as well as the need for CUI inspection protocols.

Heat-Flex TICs themselves create a barrier that prevents moisture and condensation from coming into contact with the metal substrate. They simply require periodic visual inspection to ensure that the coatings are intact and continue to provide corrosion protection. In addition, coated surfaces can be touched up when necessary.

Process Protection: Maintaining Operating Temperatures

When first installed, traditional insulation systems are very effective at keeping heat within covered assets. However, the resulting high insulation R-values can decrease rapidly if moisture infiltrates a jacketed insulation system, which is common. That moisture displaces the air content within the insulation that had initially provided the stated R-value. For example, typical mineral wool insulation material will lose up to 85% of its R-value when the material contains 10% water by volume (Table 1). That moisture content not only reduces the insulation value of the system, but can also lead to inconsistent thermal performance, since the moisture content of the insulation (and therefore its temperature control) can vary across an insulated asset.

Heat-Flex Hi-Temp 3500, for example, can eliminate this problem by providing consistent thermal performance for coated assets. While the coatings cannot replace insulation systems when asset operating temperatures must remain significantly high, they are especially effective for insulated assets operating at temperatures of 66°-135°C (150°-275°F). Facilities can achieve such performance by applying multiple coats, each at a dry film thickness (DFT) of approximately 20 mils, over the assets according to the desired insulating value. Facilities can work with their coatings supplier to estimate the insulation efficiency achievable with Heat-Flex TICs under ambient and process conditions. Using thermal modeling software, the supplier can help the owner determine whether the desired insulation value can be achieved with the coatings, as well as how many coats are required.

Compared with traditional insulation systems, Heat-Flex TICs have been found to be effective in providing initially lower, but consistent and predictable, insulation for pipes, tanks and vessels.

Bottom-Line Protection

The right coating can play an important role in improving workplace safety and protecting people from preventable accidental injuries. Heat-Flex TICs can replace bulky physical insulation systems and safety enclosures in a wide variety of plant applications. The coatings can improve plant safety by offering the burn protection required by OSHA or local regulations, reducing the potential for slips and falls by limiting condensation, and eliminating CUI hazards. In addition, facilities can gain these benefits while keeping process heat within coated assets. Spray-applied Heat-Flex TICs also offer the added benefits of keeping the ambient temperature more comfortable around coated assets operating at high temperatures, as well as reducing noise levels. Because the coatings can be used almost anywhere traditional insulation or isolation systems are used, all of these benefits combine to enable safer and more economical operations for plants.