Sherwin-Williams

March 19, 2024

Thermal insulating coatings (CUI) offer multiple safety advantages for manufacturing facilities

Hazards lurk in many corners of a wide range of manufacturing facilities, but they are especially present anywhere high-temperature equipment is in close proximity to personnel. Workers can easily burn their skin on hot elements such as pipes, ducts and tanks if facility owners do not take care to isolate that equipment.

Safety cages and fences are common isolation solutions that keep people away from hot surfaces. However, they can be costly to install, take up a lot of space and make access for maintenance difficult. Alternatively, traditional insulation systems can be used to eliminate bulky cages in favor of slightly less bulky materials, such as mineral wool, that are wrapped around an asset and then jacketed with aluminum or stainless steel. The sealed jacketing is intended to prevent moisture from saturating the insulating material. These insulation systems are effective at preventing burns, but they are costly to inspect and maintain and, at the same time, carry a greater risk of developing corrosion under insulation (CUI) when water penetrates the jacketing.

It may be surprising that a relatively thin layer of insulating coating material can offer an alternative to both insulation and cage systems while providing a number of benefits. Such spray-applied thermal insulative coatings (TICs) have sufficient thermal conductivity properties to keep exterior surfaces safe to touch, protecting personnel without the need for exterior insulation or isolation structures. They offer the added safety benefit of protecting workers against slips and falls by reducing the likelihood that condensation will form on coated assets and drip onto walking surfaces, such as floors, steps and walkways. In addition, the coatings effectively eliminate the worrisome problem of CUI, which can lead to downtime and dangerous leaks. Importantly, TICs can also provide some degree of heat conservation to potentially keep process heat within the coated assets, making them a practical option for many operations.

Burn Protection: How to Prevent Injuries

In high-temperature manufacturing environments, burns are a high-priority concern. A few seconds of incidental contact with a hot surface is all it takes for skin to blister and burn. In fact, the U.S. Occupational Safety and Health Administration (OSHA) sets a maximum skin temperature limit of 60°C (140°F) after being in contact with a hot surface for five seconds. No reportable injuries will occur below those thresholds. That means any asset located within about two and a half meters of where a worker may be positioned must be protected by a physical barrier, an insulation system or a TIC. It is important to keep that distance in mind, considering that a person one meter eighty centimeters tall can reach about two meters fifty centimeters with outstretched hands.

By specifying a TIC instead of a physical barrier or a traditional insulation system, facilities can eliminate the fabrication, installation and upkeep associated with those alternatives while still meeting OSHA burn protection requirements. For example, the Heat-Flex® line of TICs from Sherwin-Williams Protective & Marine includes spray-applied, waterborne acrylic coatings that contain a high volume of engineered ceramic or silica microspheres and aerogel particles with low thermal conductivity. These elements create low thermal conductivity within the final cured coating. This low thermal conductivity effectively limits the transfer of thermal energy through the coating, preventing people from being burned on assets that house internal fluids and gases at high temperatures. Facility managers should focus on any asset in a plant that has an operating temperature above 66°C (150 °F). Even dangerously hot systems, such as steam pipes and boiler ducts that can reach up to 177°C (350 °F), can be coated with a Heat-Flex TIC to prevent burns from incidental contact.

After a TIC has been applied and has dried, inspectors can use a thermesthesiometer on the coated asset to confirm that its surface temperature is within OSHA requirements for burn protection. This special instrument is required under the guidelines of ASTM C1057-17 “Standard Practice for Determination of Skin Contact Temperature from Heated Surfaces Using a Mathematical Model and Thermesthesiometer,” since a traditional surface temperature probe will not provide an accurate reading of skin temperature.

Condensation Protection: How to Reduce Slips and Falls

Because thermal coatings reduce heat transfer to the exterior surfaces of operating assets, there is a smaller temperature differential between those surfaces and the surrounding air. That means there is less chance that a cold or hot pipe will experience condensation on its surface. Such condensation carries a lesser risk of affecting the TIC system and the underlying asset, since water in contact with coatings can eventually lead to corrosion. What is more problematic is that condensation that accumulates on assets can threaten worker safety if it drips onto walking surfaces where employees may slip and fall. These incidents are one of the leading causes of accidents in plants.

Various processing operations involve both extreme cold and extreme hot temperatures, each of which increases the likelihood of condensation forming on equipment. However, Heat-Flex TICs can effectively insulate assets operating at service temperatures ranging from -51 °C (-80 °F ) to 177 °C (350 °F). This capability helps significantly reduce the temperature imbalances between a surface and the surrounding air that cause condensation. Surfaces should rarely drop below the dew point, minimizing the possibility that significant condensation will form, fall to the floor and cause a fall.

After a TIC has been applied and has dried, inspectors can use a thermesthesiometer on the coated asset to confirm that its surface temperature is within OSHA requirements for burn protection. This special instrument is required under the guidelines of ASTM C1057-17 “Standard Practice for Determination of Skin Contact Temperature from Heated Surfaces Using a Mathematical Model and Thermesthesiometer,” since a traditional surface temperature probe will not provide an accurate reading of skin temperature.

Corrosion Protection: How to Eliminate CUI (Corrosion Under Insulation)

Assets covered with traditional insulation systems face the potential for a problem common across many industries: CUI. Moisture will inevitably enter an insulation system and become trapped there, either from water that gets through the exterior jacketing or from condensation that forms on the surface of the covered asset. This moisture will never dry out, keeping water in constant contact with the substrate. If that substrate is uncoated, the steel is certain to face rapid deterioration, but even a coated substrate can eventually corrode when it is in constant contact with water, especially when that environment is enclosed and heated, unless a Heat-Flex CUI mitigation solution has been applied. Such corrosion can eventually cause a steam pipe, for example, to corrode and develop a leak that leads to system downtime at best and worker injuries at worst.

Perhaps the greatest concern with CUI is that it is hidden: lurking beneath the insulation or jacketing with limited warning signs of its existence. Therefore, insulated assets must be inspected periodically to confirm that CUI is not a problem. Ultimately, that involves removing portions of the jacketing and insulation to visually inspect the metal surface. Inspectors may also need to assess metal thickness using ultrasonic testing techniques.

The simplest way to eliminate the threat of CUI is to eliminate the insulation altogether, thereby eliminating the corrosion zone between the insulation and the substrate. This effectively removes the «under» in CUI. Insulating coatings such as Heat-Flex TICs allow facilities to do just that, since the coated surfaces do not require a physical exterior covering. There is no opportunity to trap moisture against metal surfaces, which effectively eliminates the risk of hidden CUI as well as the need for CUI inspection protocols.

Heat-Flex TICs themselves create a barrier that prevents moisture and condensation from contacting the metal substrate. They simply require periodic visual inspection to ensure that the coatings are intact and continue to provide corrosion protection. In addition, coated surfaces can be touched up when needed.

Process Protection: How to Maintain Operating Temperatures

When first installed, traditional insulation systems are very effective at keeping heat within covered assets. However, the resulting high insulation R-values can quickly decline if moisture infiltrates a jacketed insulation system, which is common. That moisture displaces the air content within the insulation that had initially provided the stated R-value. For example, typical mineral wool insulating material will lose up to 85% of its R-value when the material contains 10% water by volume (Table 1). That moisture content not only reduces the system's insulation value, but can also lead to inconsistent thermal performance, since the moisture content of the insulation (and therefore its temperature control) can vary across an insulated asset.

Heat-Flex Hi-Temp 3500, for example, can eliminate this problem by providing consistent thermal performance for coated assets. While the coatings cannot replace insulation systems when asset operating temperatures must remain significantly high, they are especially effective for insulated assets operating at temperatures of 66°-135°C (150°-275°F). Facilities can achieve such performance by applying multiple coats, each at a dry film thickness (DFT) of approximately 20 mils, over the assets depending on the desired insulating value. Facilities can work with their coatings supplier to estimate the insulation efficiency that can be achieved with Heat-Flex TICs under ambient and process conditions. Using thermal modeling software, the supplier can help the owner determine whether the desired insulation value can be achieved with the coatings, as well as how many coats are required.

Compared with traditional insulation systems, Heat-Flex TICs have been found to be effective at providing initially lower, but consistent and predictable, insulation for pipes, tanks and vessels.

Bottom-Line Protection

The right coating can play an important role in improving workplace safety and protecting people from preventable accidental injuries. Heat-Flex TICs can replace bulky physical insulation systems and safety cages in a wide variety of plant applications. The coatings can improve plant safety by offering OSHA-required burn protection, reducing the potential for slips and falls by limiting condensation, and eliminating CUI hazards. In addition, facilities can gain these benefits while keeping process heat within the coated assets. Spray-applied Heat-Flex TICs also offer the added benefits of keeping the ambient temperature more comfortable around coated assets operating at high temperatures, in addition to reducing noise levels. Because the coatings can be used almost anywhere traditional insulation or isolation systems are used, all of these benefits combine to enable safer and more economical operations for plants.

We use cookies to improve browsing and analyze traffic. You can accept or reject analytics cookies. Privacy Policy