Civil Infrastructure
Airports, ports, data centers, stadiums and railways: long-term protection for infrastructure assets that cannot stop.

Infrastructure that protects what keeps the world running
Data centers keep the digital world running. Airports move people and cargo. Ports sustain entire export chains. Railways carry commodities across thousands of kilometers. These assets share one non-negotiable requirement: protection systems that last decades with minimal maintenance - because a planned shutdown costs far more than the coating maintenance itself. Sherwin-Williams P&M has reference cases in all of these markets across Latin America - and specifies systems that comply with the industry's most demanding standards.
LATAM reference cases
Mission-critical projects in Latin America
International Airport
FIRETEX® on steel structures of critical infrastructure.
Google Data Center
High-performance corrosion protection on a mission-critical structure.
National Stadium
Steel structure coating with a high-durability atmospheric system.
Applications by infrastructure type
Airports
Covered steel structures: FIRETEX® FX6010 for PFP + Zinc Clad® + Acrolon® for corrosion protection. Exposed external structures: C4/C5 system with Sher-Loxane® topcoat.
Ports and marine terminals
C5-M system: inorganic Zinc Clad® + Dura-Plate® + Sher-Loxane®. Wharf structures and dolphins: splash-zone protection with an immersion system.
Railways and viaducts
Steel structures exposed to urban C3/C4 environments: zinc-rich primer + epoxy intermediate + polyurethane or polysiloxane topcoat per environment category.
Stadiums and arenas
Metal roofing and steel structure with aesthetic requirements: Zinc Clad® + Macropoxy® + Acrolon® or Sher-Loxane® with a project-specific color scheme.
Road bridges and viaducts
DNIT/ABNT-type corrosion protection system: inorganic zinc primer + epoxy intermediate + PU or polysiloxane finish - C3 to C5 per exposure category.
Key products

Zinc Clad® IV
High-performance cathodic protection for structural steel. Widely specified for bridges, viaducts and public infrastructure works.
Learn moreAcrolon® 7700
High gloss and color retention finish for exposed structures. Excellent resistance to UV, acid rain and weathering in C3/C4 environments.
Learn more
FIRETEX® FX6010
Passive fire protection for steel structures in airports, data centers and stadiums - 30 minutes to 2 hours depending on system and thickness.
Learn more
Sher-Loxane® 800
Premium isocyanate-free finish for projects demanding maximum durability, low VOC and color retention in C4/C5 environments.
Learn moreStandards and compliance
ISO 12944 C3–C5
Atmospheric corrosivity categories - the basis for system specification in airports, ports and urban infrastructure.
DNIT / ABNT
Brazilian standards for corrosion protection of special structures (bridges and viaducts) - primer, intermediate and finish systems.
EN 1337 / EN 15048
For connectors and joints in steel infrastructure - coating compatibility with fastening elements.
ISO 13438
Requirements for geosynthetics and coatings in large-scale civil infrastructure works.

Talk to people who understand your asset, not just paint